Use the voltage transient as a time-resolved resistance measurement. Apply a controlled current pulse and record the cell voltage with sufficient bandwidth from the first microseconds or milliseconds through the full pulse and relaxation period. The instantaneous voltage step estimates the Ohmic contribution, while progressively slower voltage changes can be separated into SEI transport, charge transfer, and solid-state diffusion by fitting the response to a physically informed transient model across multiple pulse durations.
The key is not to assign all measured pulse resistance to a single value. Resolve the voltage response by its characteristic time scale, then validate each fitted contribution against SOC, temperature, current amplitude, pulse duration, and independent EIS or material measurements.
What the Pulse Response Contains
Start with the instantaneous voltage step
For a current step from (I_0) to (I_1), measure the voltage change immediately after the step:
[ R_{\Omega} \approx \frac{\Delta V_{\Omega}}{|\Delta I|} ]
This earliest response represents uncompensated Ohmic resistance, including current collectors, tabs, electronic contacts, conductive networks, electrolyte, separator, and other series pathways.
The measurement must account for tester response time, wiring inductance, contact resistance, and voltage-sampling delay. Otherwise, part of the true Ohmic drop may be incorrectly assigned to a faster polarization process.
Separate series resistance from polarization
The total apparent resistance at a later time is:
[ R_{\text{app}}(t)=\frac{\Delta V(t)}{|\Delta I|} ]
It can be represented conceptually as:
[ R_{\text{app}}(t)
R_{\Omega} + R_f(t) + R_{ct}(t) + R_{\text{diff}}(t) ]
Here, the latter three terms are generally time-dependent impedance contributions, rather than perfectly constant resistors. Their apparent values depend on SOC, temperature, current, electrode state, and the time at which the voltage is sampled.
Identify Contributions by Their Time Scales
SEI film resistance: the fastest polarization process
Lithium-ion transport through the SEI produces a rapid voltage response after the Ohmic step. It is commonly represented by a film resistance (R_f), often paired with a film-related capacitance in an equivalent circuit.
On a semi-logarithmic time plot, the SEI-related feature appears immediately after the uncompensated voltage step. Its contribution can be estimated from the voltage increment over the associated short time window:
[ R_f \approx \frac{\Delta V_f}{|\Delta I|} ]
The exact time range is cell-dependent. A thicker, less conductive, or chemically altered SEI usually increases this fast polarization component, but the pulse data alone may not always distinguish SEI transport from other very fast processes.
Charge-transfer resistance: the early transient
The interfacial charge-transfer contribution develops after the fastest film response and governs much of the early discharge period. It reflects the kinetics of the electrochemical reaction at the electrode/electrolyte interface.
A common dynamic representation is a parallel (R_{ct})-(C_{dl}) branch:
[ \Delta V_{ct}(t)
\Delta I R_{ct} \left(1-e^{-t/\tau_{ct}}\right) ]
where:
[ \tau_{ct}=R_{ct}C_{dl} ]
The resistance associated with this stage is estimated from the amplitude and time constant of the early transient. Because charge-transfer kinetics are strongly temperature-dependent, repeating the pulse at different temperatures is especially useful for confirming that the identified process is interfacial rather than Ohmic.
Solid-state diffusion: the later response
Lithium diffusion through active-material particles produces a slower concentration-polarization response. It becomes increasingly visible at longer pulse times and during relaxation after the current is removed.
Unlike a simple resistor, diffusion is often represented by a finite-length Warburg element or another diffusion impedance model. The voltage may continue changing throughout the pulse rather than approaching a single exponential plateau.
The diffusion contribution can be estimated by fitting the late-time voltage response to the appropriate diffusion model:
[ \Delta V_{\text{diff}}(t)
|\Delta I|,Z_{\text{diff}}(t) ]
Longer pulses are essential because a short millisecond pulse may capture Ohmic, SEI, and charge-transfer behavior while failing to develop a measurable bulk-diffusion contribution.
Build a Time-Resolved Test Method
Use a controlled current step
Apply a reproducible current pulse at a defined SOC and temperature, then record voltage at a sampling rate fast enough to resolve the earliest response. Include both the pulse-on transient and the relaxation response after the current returns to zero.
A single pulse duration is insufficient for reliable separation. Use a sequence of pulse widths so that the experiment probes the fast film and kinetic processes as well as the slower diffusion process.
Analyze the voltage on a semi-logarithmic time axis
Plot the voltage deviation from the pre-pulse value against (\log(t)). The characteristic regions typically appear as:
- Immediate step: uncompensated Ohmic resistance.
- Fast transient: SEI film transport.
- Early-time transient: charge transfer and double-layer dynamics.
- Late-time curvature or slope: solid-state diffusion.
The three-stage polarization behavior described in the primary reference refers to the processes after the immediate Ohmic step: fast SEI transport, early charge transfer, and later diffusion.
Fit the complete transient, not isolated points
A practical equivalent-circuit structure may contain:
- A series (R_{\Omega}) element.
- An SEI branch containing (R_f) and a film capacitance.
- A charge-transfer branch containing (R_{ct}) and double-layer capacitance (C_{dl}).
- A finite-length diffusion impedance for solid-state transport.
Fit the entire voltage trace simultaneously rather than calculating one resistance from each arbitrary time point. The fitted parameters should reproduce both the pulse response and the relaxation response.
Repeat the measurement across operating conditions
Repeat pulses over relevant SOC and temperature ranges. This is necessary because internal resistance is not a fixed cell constant.
Temperature sensitivity is informative: charge-transfer resistance commonly increases strongly at low temperature, while Ohmic and diffusion contributions may show different dependence. SOC trends can also reveal diffusion limitations or electrode-specific kinetic bottlenecks.
Validate the Assignments
Compare pulse results with EIS
Electrochemical impedance spectroscopy provides frequency-domain evidence for the same processes. A high-frequency intercept is associated mainly with series Ohmic resistance, higher-frequency arcs can contain film behavior, a mid-frequency arc commonly reflects charge transfer, and low-frequency behavior is associated with diffusion.
Pulse fitting and EIS should be compared at matched SOC, temperature, and rest history. Agreement across both time and frequency domains provides stronger evidence than either technique alone.
Use electrode-level or half-cell measurements
Full-cell pulse data combine positive-electrode, negative-electrode, electrolyte, separator, and contact contributions. They cannot always uniquely determine which electrode is responsible for a measured resistance.
Reference electrodes, symmetric cells, half-cells, or post-test surface characterization can help assign the full-cell contribution to a specific electrode or interface.
Check parameter identifiability
Several processes can have overlapping time constants. If the sampling bandwidth is too low, SEI and charge-transfer effects may appear as one combined fast transient. If the pulse is too short, diffusion parameters may be weakly constrained.
Use confidence intervals, residual plots, and sensitivity analysis. A model that fits the voltage trace but produces unstable or highly correlated parameters should not be treated as proving that each physical resistance has been independently measured.
Understanding the Trade-offs
A pulse resistance is not a universal material property
The value calculated from (\Delta V/|\Delta I|) depends on the sampling time. An instantaneous resistance, a 10 ms resistance, and a 10 s resistance describe different portions of the cell's dynamic response.
Report the pulse amplitude, pulse width, sampling time, SOC, temperature, rest period, and current direction with every resistance value.
Equivalent-circuit elements are model-dependent
The labels (R_f), (R_{ct}), and (Z_{\text{diff}}) are physically useful, but fitted values depend on the selected circuit and parameter constraints. A distributed SEI, porous electrode, or nonuniform reaction surface may not behave like a single ideal resistor-capacitor branch.
Use the simplest model that explains the data, then verify that its parameters remain physically reasonable across conditions.
High current improves signal but increases nonlinearity
Larger pulses make small voltage contributions easier to detect, but they can create concentration gradients, heating, nonlinear kinetics, and SOC changes during the pulse. These effects violate the assumptions behind small-signal linear models.
Use several current amplitudes. If the extracted parameters change substantially with amplitude, interpret the result as a nonlinear operating-point response rather than a constant resistance.
Instrument artifacts can mimic fast resistance
Cable resistance, contact resistance, inductive effects, current overshoot, and voltage-channel synchronization errors are particularly important during the earliest part of the pulse.
Characterize the tester and fixture with a low-inductance reference or shorting measurement, and subtract or model the fixture contribution before interpreting the cell response.
Making the Right Choice for Your Goal
Use the test design that matches the engineering question:
- If your primary focus is high-power capability: Extract (R_{\Omega}), (R_f), and (R_{ct}) from the earliest response, then use longer pulses to determine whether diffusion adds a substantial late-time voltage loss.
- If your primary focus is mechanism identification: Combine semi-log pulse analysis with EIS, temperature sweeps, and multiple pulse durations so that time constants and physical assignments can be cross-validated.
- If your primary focus is production or cell screening: Use a fixed SOC, temperature, pulse amplitude, and sampling time, and report a defined time-specific resistance rather than treating it as the cell's universal internal resistance.
- If your primary focus is degradation analysis: Track the fitted Ohmic, film, charge-transfer, and diffusion parameters separately over aging, while checking that changes are not caused by altered SOC, temperature, rest time, or model non-identifiability.
A reliable pulse test turns the cell's transient voltage response into a time-resolved map of its internal bottlenecks, provided each contribution is interpreted through a validated dynamic model rather than a single resistance value.
Summary Table:
| Contribution | Time Scale | How to Identify |
|---|---|---|
| Ohmic | Instantaneous | Immediate voltage step after current pulse |
| SEI film | Very fast (milliseconds) | Early transient after Ohmic step |
| Charge transfer | Early (milliseconds to seconds) | Exponential voltage change with time constant Rct*Cdl |
| Solid-state diffusion | Slow (seconds to minutes) | Late-time voltage curvature or slope during pulse/relaxation |