A second discharge plateau in nickel oxide electrodes is usually an interfacial conduction phenomenon, not evidence of a new bulk discharge phase. As discharge proceeds, the electrode becomes more resistive and its internal semiconductor junctions develop additional potential drops. These drops can enable continued discharge at a lower measured voltage, producing a secondary plateau typically observed around −0.1 to −0.6 V versus Hg/HgO, below the primary 0.25–0.35 V versus Hg/HgO plateau.
The lower plateau forms when depletion and barrier layers near the current collector become sufficiently polarized to conduct charge through otherwise resistive nickel hydroxide/oxide material. State of charge, proton transport, electrode microstructure, and aging determine how strongly it appears.
Why the electrode develops a second plateau
Discharge changes the electrode’s electronic conductivity
The nickel electrode is not an ideally metallic conductor. Its active material can behave as a degenerate semiconductor at higher state of charge, but become substantially more resistive as the available charged nickel species are depleted.
At that point, the potential measured at the current collector no longer represents the electrochemical potential uniformly throughout the active material. A significant fraction of the applied voltage is lost inside the electrode.
A depletion layer forms near the conductive substrate
The active material immediately adjacent to the current collector or sinter matrix can become depleted first. This creates a semiconducting depletion layer between the conductive substrate and the remaining electrochemically active material.
As the depletion layer grows or becomes more resistive, the electrode voltage shifts in the negative direction. A further voltage drop across this thin region can then increase its electronic conductivity enough to allow discharge to continue into material farther from the collector.
This produces a lower-voltage region in the discharge curve rather than an abrupt end of capacity.
Which internal junctions contribute
Current collector–NiOOH Schottky junction
The metallic current collector in contact with n-type NiOOH can form a Schottky junction. This junction behaves as an electronic barrier whose resistance and voltage drop depend on the local polarization and charge state.
During discharge, the junction can contribute to the initial voltage response and to the redistribution of potential within the electrode.
Ni(OH)₂–NiOOH p–n junction
The interface between Ni(OH)₂ and NiOOH can behave as a p–n junction because the two nickel oxyhydroxide states have different electronic conduction properties.
As discharge changes the relative amounts and local distribution of these phases, the junction’s built-in field and resistance change. The resulting internal potential gradients can contribute to the transition from the primary plateau to the lower plateau.
Current collector–Ni(OH)₂ Schottky junction
Near the end of discharge, the current collector may contact increasingly resistive Ni(OH)₂. This creates another Schottky-type barrier.
The primary plateau can therefore give way to a condition in which a substantial voltage drop is required across the collector–active-material interface before sufficient electronic conduction is established. Once that condition is reached, the electrode can continue discharging at the secondary, lower potential.
Why the plateau appears only after substantial discharge
Increasing polarization drives the transition
As current passes, the electrode potential becomes more negative. This polarization increases the hole conductivity of the resistive Ni(OH)₂ region, helping charge move through the depleted interface.
The electrode consequently enters a different conduction regime: the lower voltage is not simply the equilibrium potential of a new material phase, but the result of electrochemical reaction coupled with field-assisted electronic transport.
Proton transport may become rate-limiting
The active material also depends on proton movement to maintain the charged sites required for normal reaction. At low state of charge, proton diffusion through the active material may not keep pace with the imposed discharge current.
This leaves the region near the conductive substrate depleted and establishes a potential gradient across it. The gradient increases electronic conductivity through the depleted layer, allowing additional low-voltage discharge.
The measured voltage includes internal voltage losses
Laboratory battery equipment measures the terminal or working-electrode potential, which includes both the reaction potential and internal losses. During the second plateau, the measured voltage is strongly influenced by:
- Semiconductor depletion-layer resistance
- Schottky and p–n junction polarization
- Electronic transport through resistive Ni(OH)₂
- Proton diffusion limitations
- Current-collector and active-material contact resistance
The plateau therefore reflects the coupled electrochemical and electronic behavior of the entire electrode structure.
Why electrode construction affects the second plateau
Electrode density controls transport distances
Higher or nonuniform compaction can lengthen proton and electron transport paths or create regions with poor contact to the current collector.
The resulting local depletion is more likely to produce a pronounced secondary plateau. Density must therefore be optimized rather than maximized indiscriminately.
Conductive pathways determine barrier severity
Poor mixing, insufficient conductive additive, or weak contact with the sinter matrix increases the fraction of active material that depends on a resistive interfacial path.
A well-connected electronic network reduces internal voltage losses and can suppress or reduce the capacity appearing on the lower plateau.
Microstructural uniformity matters
Nonuniform active-material distribution causes some regions to reach depletion earlier than others. This broadens the transition and can make the secondary plateau appear more pronounced or less sharply defined.
How aging can increase the lower-plateau capacity
Interfacial degradation shifts capacity downward
Sinter corrosion, active-material migration, electrode swelling, and loss of electrical contact can isolate active material from the current collector.
The material may remain chemically present but require a larger internal voltage drop to conduct. More of the nominal capacity is then delivered on the secondary plateau instead of the primary plateau.
Some changes are recoverable
Moderate changes associated with precharge loss, minor corrosion, or altered polarization may be partly reversible through controlled charging or reconditioning.
Testing should distinguish a temporary voltage-profile shift from permanent structural or contact degradation.
Some changes are irreversible
Physical damage, severe swelling, active-material isolation, and unfavorable low-voltage exposure can permanently expand the lower-plateau capacity.
In that case, the secondary plateau is a diagnostic signature of lost electrode utilization, not merely an altered operating condition.
Understanding the Trade-offs
Do not automatically interpret the plateau as a new phase
A secondary plateau can resemble a phase-transformation feature in a voltage profile. However, for nickel oxide electrodes, the primary explanation is often semiconductor junction formation and depletion-layer conduction, especially when the plateau depends strongly on current, electrode density, or contact quality.
Phase changes may still occur in the electrode, but the lower plateau should not be assigned to a new phase without complementary structural or chemical evidence.
Do not confuse cell-level and electrode-level voltage ranges
The reported potential depends on the reference system. Values such as −0.1 to −0.6 V versus Hg/HgO for an electrode test should not be directly compared with lower plateaus reported as 0.8–1.0 V in a complete nickel-based cell.
The latter includes the opposing electrode and cell configuration. Reference-electrode identity and cell architecture must be recorded when comparing results.
Higher current can exaggerate the effect
A higher discharge rate increases polarization and transport gradients. It can therefore make the second plateau appear earlier, lower, or larger even if the underlying electrode has not structurally degraded.
Rate-dependent testing is necessary to separate intrinsic interfacial behavior from kinetic limitations.
A lower plateau is not automatically unusable capacity
The secondary plateau can represent genuine continued discharge of active material. However, its lower voltage, greater heat generation, and increased internal losses may make that capacity unsuitable for the intended operating window.
The practical question is not only whether capacity remains, but whether it remains available at an acceptable voltage and efficiency.
How to diagnose the mechanism with laboratory testing
Compare different discharge currents
Run controlled discharge tests at multiple current densities. A plateau that shifts substantially with current is likely to contain a strong polarization or transport component.
A relatively stable plateau is more consistent with a dominant equilibrium or phase-related contribution, although this test alone is not conclusive.
Track plateau capacity over cycling
Use periodic full or deep discharges to quantify capacity delivered on the primary and secondary plateaus separately.
Growth of the secondary-plateau fraction indicates increasing interfacial resistance, active-material isolation, precharge depletion, or structural degradation.
Vary electrode density and conductivity
Comparing pressing density, conductive-additive content, and current-collector contact quality can reveal whether the phenomenon is controlled by transport and junction resistance.
A strong improvement after changing the conductive network supports an interfacial electronic explanation.
Correlate voltage with heat and impedance
The lower plateau may be accompanied by increased heat generation because more energy is dissipated across resistive layers and junctions.
Impedance measurements, temperature monitoring, and high-resolution voltage tracking can help distinguish internal resistance growth from a true change in reaction potential.
Making the Right Choice for Your Goal
-
If your primary focus is identifying the electrochemical origin: Treat the second plateau first as a depletion-layer and semiconductor-junction effect, then use structural analysis to determine whether any separate phase transformation also contributes.
-
If your primary focus is diagnosing electrode aging: Trend the capacity and duration of the secondary plateau over repeated deep discharges, while monitoring impedance, temperature, and active-material contact.
-
If your primary focus is improving electrode design: Optimize active-material density, conductive pathways, proton transport, and current-collector contact to minimize interfacial voltage loss.
-
If your primary focus is obtaining reliable test data: Report the reference electrode, discharge rate, electrode loading, density, depth of discharge, and cell configuration so electrode-level and full-cell plateau voltages are not conflated.
A second discharge plateau is best understood as a voltage signature of state-dependent transport and interfacial semiconductor behavior within the nickel electrode.
Summary Table:
| Mechanism | Description | Key Factors |
|---|---|---|
| Depletion layer formation | Resistive layer near current collector causes voltage drop, enabling lower-voltage discharge. | State of charge, electrode density, conductivity |
| Schottky junction (collector-NiOOH) | Electronic barrier at interface contributes to potential drop and redistribution. | Current collector material, oxide doping |
| p-n junction (Ni(OH)2-NiOOH) | Interface between phases acts as junction, altering built-in field and resistance. | Phase distribution, discharge depth |
| Proton transport limitation | Slow proton diffusion creates potential gradient, increasing electronic conduction through depleted layer. | Discharge rate, electrode microstructure |
| Aging and degradation | Interfacial degradation and isolation increase lower-plateau capacity. | Cycling history, mechanical integrity |
Unlock deeper insights into your battery materials with KINTEK's advanced laboratory equipment. Our portfolio covers the entire cell fabrication workflow—from slurry mixing and coating to precision pressing and testing systems. Whether you're optimizing nickel oxide electrodes or pushing the boundaries of energy storage, our tools help you diagnose mechanisms, improve design, and accelerate innovation. Contact us today to see how we can support your research and development goals. Get in touch with our team and elevate your battery testing capabilities!