Products Battery Testing & Electrochemical Equipment In-situ Raman Test Cell Air Fuel Cell Test Equipment Electrolyte Circulation Pump
Air Fuel Cell Test Equipment Electrolyte Circulation Pump

In-situ Raman Test Cell

Air Fuel Cell Test Equipment Electrolyte Circulation Pump

Item Number : BE01

Price varies based on specs and customizations


Pump Flow Rate
300–600 mL/min
Flow Selection
Four flow levels
Material Resistance
Resistant to acids and alkalis
ISO & CE icon

Shipping:

Contact us to get shipping details Enjoy On-time Dispatch Guarantee.

View Specs

Why Choose Us

Easy ordering process, quality products, and dedicated support for your business success.

Easy Process Quality Assured Dedicated Support

Product Overview

Product image 1

Product image 3

This electrolyte circulation pump is an auxiliary component for air fuel cell test equipment. It provides controlled electrolyte movement through the test system, supporting stable liquid circulation during air fuel cell research and evaluation. The sealed construction helps contain the working fluid, while convenient connections simplify integration with compatible test equipment.

Designed for electrolyte circulation rather than complete cell testing, this unit addresses an important part of the fuel cell test workflow. By maintaining circulation at selectable flow levels, the equipment helps reduce anode passivation and polarization during operation. The pump is therefore suited to laboratories and research teams that need repeatable electrolyte management alongside an air fuel cell test platform.

All wetted materials are resistant to both acids and alkalis, supporting use with a broad range of electrolyte conditions. The combination of sealed design, selectable flow, and chemical resistance provides a practical solution for demanding laboratory testing where liquid compatibility and consistent operation are important.

Key Features

  • Dedicated Electrolyte Circulation: Designed specifically as the electrolyte circulation equipment within an air fuel cell test setup, this unit supports controlled movement of electrolyte during fuel cell research and evaluation.

  • Selectable Four Level Flow: Four flow settings allow operators to select an appropriate circulation condition for different testing requirements. This supports more consistent comparisons between experiments and helps users adjust liquid movement without replacing the circulation unit.

  • 300–600 mL/min Pump Flow: The pump provides a flow range of 300–600 mL/min. This operating range supports practical electrolyte circulation while giving the user flexibility to match the liquid movement to the test condition.

  • Sealed Construction: The sealed design helps limit exposure of the circulating electrolyte to the external environment and supports more controlled operation. It is suitable for laboratory workflows where containment and connection integrity are important.

  • Acid and Alkali Resistance: All materials used in the equipment are resistant to acids and alkalis. This material selection improves compatibility with electrolyte environments and supports dependable use across varied research conditions.

  • Convenient Connections: Connection points are designed for convenient integration with the associated test system. This helps reduce setup complexity when installing the circulation equipment as part of an air fuel cell testing workflow.

  • Reduced Anode Passivation: Electrolyte circulation can effectively reduce anode passivation during the reaction. This helps maintain a more suitable reaction environment for evaluating fuel cell behavior.

  • Lower Polarization: By circulating the electrolyte, the unit helps reduce polarization in the reaction process. The result is improved control of an important operating factor during air fuel cell testing.

  • Laboratory Focused Design: The equipment concentrates on the electrolyte management function, making it a practical addition for research teams that already have an air fuel cell test device or are assembling a modular test platform.

Applications

Application Description Key Benefit
Air Fuel Cell Performance Testing Circulates electrolyte during controlled air fuel cell experiments and supports the liquid-management portion of the test setup. Helps maintain repeatable electrolyte movement across test runs.
Anode Reaction Research Supports experiments focused on anode behavior by circulating electrolyte through the reaction system. Helps reduce anode passivation during operation.
Polarization Evaluation Provides electrolyte circulation during studies of reaction polarization and operating response. Helps reduce polarization and improve control of test conditions.
Electrolyte Compatibility Studies Uses acid- and alkali-resistant materials for testing workflows involving different electrolyte environments. Supports broader electrolyte application compatibility.
Fuel Cell Component Screening Adds controlled circulation to laboratory screening of air fuel cell components and reaction configurations. Provides a practical, adjustable circulation condition for comparative testing.
Academic Electrochemical Research Integrates with laboratory air fuel cell research conducted by universities and materials laboratories. Offers a compact auxiliary function for repeatable experimental setups.
Modular Test System Construction Serves as the electrolyte circulation component when researchers configure or expand an air fuel cell test arrangement. Simplifies the separation of circulation and testing functions.

Technical Specifications

Parameter Specification
Product Item Number BE01
Product Type Electrolyte circulation equipment for air fuel cell test equipment
Primary Function Circulation of electrolyte during air fuel cell testing and research
Pump Flow Rate 300–600 mL/min
Flow Selection Four flow levels
Design Sealed design
Connections Convenient connection design
Material Resistance Resistant to acids and alkalis
Intended Integration Air fuel cell test equipment
Included Function Electrolyte circulation
Testing Equipment Status The price does not include the air fuel cell testing equipment
Circulation Effect Helps reduce anode passivation and polarization through electrolyte circulation

The stated flow range is 300–600 mL/min, with four available flow levels. Operators can select among the available levels according to the electrolyte circulation condition required by the experiment. Because the circulation unit is an auxiliary component, the complete test capability depends on the compatible air fuel cell testing equipment used with it.

The sealed construction and acid- and alkali-resistant materials are central to the equipment's intended operating environment. These characteristics support use with electrolyte circulation where chemical exposure and connection reliability must be considered during setup. The unit is intended to be connected to an air fuel cell test arrangement rather than used as a standalone fuel cell analyzer or complete testing platform.

Electrolyte circulation is also the main performance-related function described for this equipment. During the reaction, circulation can effectively reduce anode passivation and decrease polarization. These effects make the unit useful when researchers need to improve control over the electrolyte side of an air fuel cell experiment and compare reaction behavior under different circulation settings.

Why Choose This Product

  • Purpose Built for Electrolyte Management: The unit focuses on a clearly defined requirement within air fuel cell testing: stable and adjustable electrolyte circulation. This makes it easier to specify as part of a modular laboratory setup.

  • Chemically Resistant Construction: Acid- and alkali-resistant materials provide a practical foundation for electrolyte handling and support dependable operation across relevant laboratory conditions.

  • Adjustable Operating Conditions: Four flow levels within a 300–600 mL/min range give researchers useful control over circulation conditions, supporting repeatable testing and comparison between experiments.

  • Reliable Sealed Design: The sealed configuration supports contained operation and convenient system connection, helping the equipment fit efficiently into a structured fuel cell research workflow.

  • Focused Reaction Support: By circulating electrolyte, the unit helps reduce anode passivation and polarization, supporting more controlled air fuel cell reaction studies.

Contact us for a quotation and application-specific configuration guidance for your air fuel cell testing and electrolyte circulation requirements.

Trusted by Industry Leaders

Our Cooperated Clients
View more faqs for this product

Product Datasheet

Air Fuel Cell Test Equipment Electrolyte Circulation Pump

Category Catalog

In-Situ Raman Test Cell


REQUEST A QUOTE

Our professional team will reply to you within one business day. Please feel free to contact us!

Related Products

Laboratory Hydraulic Hot Press for Solid-State Battery Electrolytes and Polymer Composites

Laboratory Hydraulic Hot Press for Solid-State Battery Electrolytes and Polymer Composites

Explore advanced uniform thermal pressing for solid-state battery electrolytes and polymer composites using a laboratory hydraulic hot press featuring independent dual-platen precise PID temperature control up to 300°C, programmable pressure, and automatic force compensation for reliable consistent results.

View Details
Single Head Electrolyte Filling Pump Precision Ceramic Metering System

Single Head Electrolyte Filling Pump Precision Ceramic Metering System

Single head electrolyte filling pump provides precise low volume metering for lithium ion batteries pharmaceuticals food chemicals and adhesive fluids with durable ceramic valve technology easy cleaning reliable programmable operation for demanding production environments and flexible OEM integration

View Details
Laboratory Hydraulic Hot Press for Solid-State Battery and Polymer Electrolyte Research

Laboratory Hydraulic Hot Press for Solid-State Battery and Polymer Electrolyte Research

Compact benchtop hydraulic hot press for solid-state battery and polymer electrolyte research with dual-zone heating, automatic pressure compensation, and active cooling system, ensuring uniform temperature up to 300°C and stable load for extended tests with CE certification and safety features.

View Details
Laboratory Benchtop Hydraulic Hot Press for Solid State Battery Research

Laboratory Benchtop Hydraulic Hot Press for Solid State Battery Research

Explore the laboratory hydraulic hot press for solid-state battery research, featuring dual-platen heating, automated pressure profiling, and integrated water cooling for efficient, precise sample processing. Ideal for electrolyte pellet and membrane fabrication in a compact, glovebox-compatible benchtop design.

View Details
Laboratory Hydraulic Hot Press for Solid-State Battery Research

Laboratory Hydraulic Hot Press for Solid-State Battery Research

Compact benchtop hydraulic hot press for solid-state battery research, with dual heated platens, programmable touchscreen, and precise temperature control up to 300°C and 5 tons force. Ideal for electrolyte synthesis and electrode lamination, with automatic pressure holding. CE certified.

View Details
Programmable Laboratory Hydraulic Hot Press for Solid-State Battery Fabrication

Programmable Laboratory Hydraulic Hot Press for Solid-State Battery Fabrication

Hydraulic hot press with 75 tons force programmable pressure control dual-zone heating up to 300°C ideal for solid-state battery electrolyte consolidation polymer composite curing electrode lamination features automatic pressure compensation adjustable ramp rates water cooling customizable options CE certified.

View Details
Solid-State Battery and Polymer Electrolyte Development Laboratory Hydraulic Hot Press Machine

Solid-State Battery and Polymer Electrolyte Development Laboratory Hydraulic Hot Press Machine

High-precision benchtop hydraulic hot press for solid-state battery and polymer electrolyte research. Features dual heated platens up to 300°C, automatic pressure compensation up to 15T, and integrated water cooling for repeatable results. Ideal for electrolyte compaction and PEMFC pressing.

View Details
Laboratory Hydraulic Hot Press for Solid State Battery and MEA Fabrication

Laboratory Hydraulic Hot Press for Solid State Battery and MEA Fabrication

Compact laboratory hydraulic hot press with independent dual platen heating up to 300°C and programmable 50 ton pressure for solid state battery electrolyte compaction and membrane electrode assembly fabrication, featuring water cooling and safety shields, suitable for advanced material research.

View Details
Solid State Battery Research Laboratory Hydraulic Hot Press Machine

Solid State Battery Research Laboratory Hydraulic Hot Press Machine

Benchtop hydraulic hot press designed for solid-state battery research. Offers dual-platen heating to 500°C, 40-ton pressure with closed-loop control, and a 7-inch touchscreen. Supports electrolyte fabrication, electrode lamination, and polymer molding with safety shields and thermal cut-offs.

View Details
Laboratory Hydraulic Hot Press Machine for Solid-State Battery Research

Laboratory Hydraulic Hot Press Machine for Solid-State Battery Research

Compact benchtop laboratory hydraulic hot press for solid-state battery research featuring independent dual-zone heating up to 300°C, 25-ton automatic pressure control, and integrated water cooling for precise compaction of electrolytes and polymer membranes in small-footprint design ideal for R&D applications.

View Details
Solid-State Battery Laboratory Hydraulic Hot Press Machine

Solid-State Battery Laboratory Hydraulic Hot Press Machine

Precision laboratory hydraulic hot press for solid-state battery research. Features servo-driven 0-4 ton pressure, dual-plate independent heating up to 300°C, active water cooling, and 7-inch touchscreen control. Ideal for electrolyte and electrode fabrication. Ensures oil-free operation for reproducible results.

View Details
Isobaric High Precision Aluminum Shell Battery Liquid Injection Machine

Isobaric High Precision Aluminum Shell Battery Liquid Injection Machine

Isobaric aluminum shell battery liquid injection machine for lithium battery production, supporting primary and secondary filling, vacuum pressure cycling, sealed positive pressure glovebox operation, accurate dosing, weighing, and stable high yield for demanding laboratory manufacturing workflows and advanced materials research.

View Details
Solid State Battery Research Laboratory Hydraulic Hot Press Machine

Solid State Battery Research Laboratory Hydraulic Hot Press Machine

High-precision thermal compression system for solid-state battery research with independent dual-platen heating up to 300°C, 30-ton hydraulic press, and automatic pressure compensation for precise sample fabrication. Ideal for electrolyte compaction and composite lamination. With programmable cooling and safety interlocks.

View Details
Automatic Laboratory Hydraulic Press for XRF and KBR Pellet Pressing

Automatic Laboratory Hydraulic Press for XRF and KBR Pellet Pressing

KinTek XRF Pellet Press: Automated sample prep for precise XRF/IR analysis. High-quality pellets, programmable pressure, durable design. Boost lab efficiency today!

View Details
Solid-State Battery Laboratory Hydraulic Hot Press Machine

Solid-State Battery Laboratory Hydraulic Hot Press Machine

Precision laboratory hydraulic hot press for solid-state battery research, with dual-plate heating up to 300°C, 50-ton active pressure holding, programmable touchscreen control, and robust benchtop design, ideal for academic and industrial laboratories compacting electrolyte pellets and laminating electrodes.

View Details
Laboratory Hydraulic Split Electric Lab Pellet Press

Laboratory Hydraulic Split Electric Lab Pellet Press

KINTEK Split Electric Lab Press: Precision sample preparation for research. Compact, versatile, with advanced pressure control. Ideal for material studies.

View Details
Solid State Battery Research Laboratory Hydraulic Hot Press Machine

Solid State Battery Research Laboratory Hydraulic Hot Press Machine

Compact benchtop hydraulic hot press machine designed for solid-state battery research, featuring dual-zone independent heating up to 300°C, programmable pressure control with automatic replenishment, and integrated water cooling for rapid cycle times, suitable for electrolyte fabrication and electrode lamination.

View Details
Solid-State Battery Research Laboratory Hydraulic Hot Press Machine

Solid-State Battery Research Laboratory Hydraulic Hot Press Machine

Designed for solid-state battery research, this laboratory hydraulic hot press features servo-driven pressurization up to 2 tons, dual-platen heating up to 300°C, programmable pressure cycles, and a 7-inch touch-screen controller for precise thermal compaction of electrolytes and electrodes.

View Details
Handheld Circular Cutting Machine for Lithium Battery Electrode Samples

Handheld Circular Cutting Machine for Lithium Battery Electrode Samples

Handheld circular cutting machine for lithium battery electrodes delivers one stroke cutting with burr free smooth edges and customizable dies for precise laboratory sample preparation and repeatable research workflows across pilot development and advanced materials laboratories with dependable operation

View Details
Plunger Pump Feeding Device for Adjustable Laboratory Slurry Delivery and Coating Equipment

Plunger Pump Feeding Device for Adjustable Laboratory Slurry Delivery and Coating Equipment

Plunger pump feeding device with adjustable piston speed, anti-drip stopping, interchangeable PP syringes, PTFE tubing, coating machine integration, compact construction, and reliable slurry metering for battery electrode, laboratory coating, and advanced materials research workflows requiring controlled continuous delivery

View Details