Battery Testing Equipment
5V 5A Lithium Ion Battery Testing Equipment Battery Tester
Item Number : DC13
Price varies based on specs and customizations
- Voltage Range per Channel
- Charge: -5 ~ +5V; discharge: +5 V ~ -5V
- Current Range per Channel
- 0.1uA---5000mA across four selectable ranges
- Device Main Channel Quantity
- 4
Shipping:
Contact us to get shipping details Enjoy On-time Dispatch Guarantee.
Why Choose Us
Easy ordering process, quality products, and dedicated support for your business success.
Product Overview

This four-channel battery testing system is designed for precise evaluation of lithium-ion cells, laboratory prototypes, and electrochemical energy-storage components. With a programmable voltage range from -5 V to +5 V and current capability up to 5 A per channel, the equipment supports controlled charge, discharge, pulse, constant-power, constant-resistance, and DCIR testing within one integrated platform.
The system serves battery R&D laboratories, cell manufacturers, materials researchers, universities, and quality-control teams. It supports routine cycling, performance verification, capacity characterization, rate testing, pulse response analysis, and development-stage validation for cylindrical, pouch, coin, and other compatible cell formats using a universal fixture.
High-resolution 16-bit AD and DA conversion, four current ranges, four-wire measurement, rapid current response, and stable output regulation help produce repeatable test results. Software protection, power-failure data protection, offline testing, and database-backed record management support dependable operation during extended test programs and demanding research schedules.
Key Features
-
Four Independent Test Channels: Four device channels allow parallel testing of multiple cells or test conditions, improving laboratory throughput while maintaining channel-level control and measurement.
-
Wide Dynamic Current Range: Four selectable current ranges cover 0.1 µA to 5 A, allowing the same system to address low-current electrochemical measurements and higher-current battery performance tests with appropriate resolution.
-
High-Precision Voltage and Current Control: Voltage and current accuracy are both specified at ±0.02% of full scale, while stability is maintained at ±0.005% of full scale for consistent charge and discharge results.
-
Fast Sampling and Current Response: Current response time is ≤100 µs from 10% to 90% or 90% to 10%. Data recording supports time intervals of at least 1 ms and continuous charge-discharge recording at 1000 Hz.
-
Flexible Charge and Discharge Programming: The equipment supports constant-current, constant-current/constant-voltage, constant-voltage, constant-power, constant-power/constant-voltage, and constant-resistance charge modes, together with multiple discharge strategies.
-
Pulse and DCIR Testing: Pulse testing supports constant-current charge and discharge, minimum pulse widths of 400 µs, and up to 16 different pulse segments within one pulse step. Dedicated DCIR measurement steps support dynamic resistance evaluation.
-
Comprehensive Protection Controls: Configurable voltage, current, capacity, and fluctuation limits help protect test articles and equipment. The software also provides power-failure data protection and offline testing capability.
-
Four-Wire Measurement Architecture: Four-wire voltage and current sensing reduces the influence of lead resistance, supporting more reliable measurements for low-voltage cells and precision characterization work.
-
Structured Data and Connectivity: A MySQL database organizes test data, while 100M Ethernet communication through TCP/IP supports host-computer operation. Results can be exported in EXCEL 2003, EXCEL 2010, and TXT formats.
Applications
| Application | Description | Key Benefit |
|---|---|---|
| Lithium-Ion Cell Development | Characterize prototype cells through controlled formation, capacity testing, rate testing, and repeated charge-discharge cycling. | Generates consistent electrochemical data for cell design decisions and formulation comparison. |
| Battery Materials Research | Evaluate electrodes, separators, electrolytes, and material modifications under programmed electrical conditions. | Supports accurate comparison of material performance across multiple test channels. |
| DCIR and Pulse Response Testing | Apply short, controlled current pulses to examine dynamic resistance, voltage response, and transient behavior. | Provides high-speed response data useful for power capability and model development. |
| Cell Quality Control | Run repeatable verification procedures for incoming cells, pilot production, or finished battery components. | Improves test consistency and creates traceable records for quality review. |
| Academic and Institutional Research | Conduct programmable experiments involving cycling, pulse loads, capacity limits, and energy measurements. | Offers broad test-method flexibility for changing research requirements. |
| Battery Pack and Power-System Evaluation | Assess cell behavior under constant-power, constant-resistance, and application-relevant current profiles. | Helps researchers understand performance under realistic operating conditions. |
Technical Specifications
| Parameter | Specification |
|---|---|
| Product item number | DC13 |
| Device main channel quantity | 4 |
| Input power supply | AC 220V +10% / -20%, 50Hz |
| Input power | 300W |
| AD resolution | 16bit |
| DA resolution | 16bit |
| Input impedance | ≥ 500MΩ in power-on state; leakage current is 100uA when powered off |
| Channel characteristics | Four ranges; wide dynamic range; high-speed sampling; high precision |
| Fixture type | Universal fixture |
| Server operating system | Windows 7 / Windows10 |
| Communication method | TCP/IP protocol, 100M Ethernet |
| Communication interface | Ethernet port |
| Database | MySQL database for test data management |
| Data output formats | EXCEL2003, 2010, TXT |
| Voltage range per channel | Charge: -5 ~ +5V; discharge: +5 V ~ -5V |
| Voltage accuracy | ± 0.02% of FS |
| Voltage stability | ±0.005% of FS |
| Single-channel output power | 25W |
| Power stability | ± 0.01% of FS |
| Current response time | <= 100μS (10% to90%or90% to 10%) |
| Minimum step time | >=10ms |
| Current range 1 | 0.1uA---150uA |
| Current range 2 | [1]50uA---5mA |
| Current range 3 | 5mA---150mA |
| Current range 4 | 150mA---5000mA |
| Current accuracy | ± 0.02% of FS |
| Current accuracy, range 1 | ± 30nA |
| Current accuracy, range 2 | ± 1uA |
| Current accuracy, range 3 | ± 30uA |
| Current accuracy, range 4 | ± 1mA |
| Current stability | ±0.005% of FS |
| Data recording condition, time interval | Time △t: >=1ms |
| Data recording condition, voltage interval | Voltage △U: >= 1mV |
| Data recording condition, current interval | Current △I: >= 100nA |
| Recording frequency | 1000Hz in continuous charge-discharge mode; individual pulse recording in GSM pulse mode |
| Charge modes | Constant-current charge; constant-current/constant-voltage charge; constant-voltage charge; constant-power charge; constant-power/constant-voltage charge; constant-resistance charge |
| Charge cutoff conditions | Voltage, current, relative time, capacity, energy, power |
| Discharge modes | Constant-current discharge; constant-power discharge; constant-resistance discharge; pulse discharge; constant-current/constant-voltage discharge |
| Discharge cutoff conditions | Voltage, current, relative time, capacity |
| Pulse charge mode | Constant-current mode |
| Pulse discharge mode | Constant-current mode |
| Minimum pulse width | 400μs |
| Pulse segments per pulse step | 16 different pulse segments |
| Pulse cutoff conditions | Voltage, pulse quantity, step time |
| DCIR testing | Supports DCIR measurement steps |
| Cycle measurement range | 1~65535 cycles |
| Steps per single cycle | 255 |
| Nested cycle function | Supports nested cycles, maximum 4 levels of nesting |
| Software protection | Power-failure data protection; offline testing capability; configurable safety protection conditions |
| Configurable safety limits | Upper voltage limit; lower voltage limit; upper current limit; lower current limit; upper capacity limit protection; voltage fluctuation protection; current fluctuation protection |
| Voltage and current detection sampling | Four-wire connection |
| Barcode scanning | Software-supported; scanner configuration enables test data binding to barcodes; scanner not included |
| Operating temperature, accuracy-guaranteed range | 25±5℃ |
| Operating temperature, limit-use range | 25±20℃ |
| Storage temperature range | 0~60℃ |
| Operating relative humidity | ≤70% RH, without water vapor condensation |
| Storage relative humidity | ≤80% RH, without water vapor condensation |
The four-channel architecture and programmable test modes allow laboratories to combine routine cycling with advanced transient measurements on the same platform. Researchers can define voltage, current, time, capacity, energy, power, and pulse-related cutoff conditions according to the test objective, helping reduce manual intervention and improve procedural consistency.
The current-range design is especially useful when a laboratory works with cells and materials that require significantly different test currents. Low-current measurements can use the lower ranges for sensitive characterization, while higher-power testing can use the 150mA---5000mA range. The specified range-dependent current accuracy values make the measurement capability easier to assess during method development and equipment selection.
Data recording is designed for both long-duration cycling and fast pulse events. Continuous charge-discharge operation can record at 1000Hz, while GSM pulse mode supports individual pulse recording. Time, voltage, and current recording thresholds can be configured at the stated minimum intervals, providing a detailed data trail for performance analysis, troubleshooting, and report preparation.
Why Choose This Product
-
Built for Long-Term Laboratory Use: A 300W input design, 25W single-channel output, stable regulation, and configurable protection functions support reliable operation across extended testing programs.
-
Measurement Quality for Research Decisions: 16-bit conversion, ±0.02% of full-scale voltage and current accuracy, ±0.005% stability, and four-wire sensing help reduce measurement uncertainty when comparing cells and materials.
-
One Platform for Multiple Test Methods: Charge, discharge, pulse, cycling, constant-power, constant-resistance, and DCIR functions provide the flexibility needed as research priorities change.
-
Traceable Digital Workflow: MySQL data management, TCP/IP Ethernet communication, barcode binding, offline testing, and common export formats make results easier to organize, retrieve, and review.
-
Practical Protection and Supportability: Configurable safety limits and power-failure data protection help preserve valuable test records and protect samples during unattended operation.
Contact us for a detailed quotation, application review, or a testing configuration matched to your cell format, current profile, and research workflow.
Trusted by Industry Leaders
Product Datasheet
5V 5A Lithium Ion Battery Testing Equipment Battery Tester
REQUEST A QUOTE
Our professional team will reply to you within one business day. Please feel free to contact us!
Related Products
Manual Multifunctional OCV Sorting Machine for Pouch Lithium Ion Cells
Manual multifunctional OCV sorting machine for pouch lithium ion cells, combining voltage and internal resistance testing, data binding, software grading, voice notification, and flexible cell compatibility.
Precision Laboratory Transfer Coating Machine for Lithium Ion Battery Electrodes
Precision laboratory transfer coating machine for lithium ion battery electrodes delivers controlled continuous and intermittent coating, uniform film application, integrated drying, and reliable winding for demanding cathode and anode pilot production with compatibility for aluminum and copper foil substrates.
Semi Automatic Cylindrical Prismatic Lithium Ion Battery Winding Machine
Semi automatic cylindrical and prismatic lithium ion battery winding machine delivers consistent electrode alignment controlled tension and high throughput for research and pilot cell production with adaptable mandrels touchscreen settings and continuous separator handling for demanding laboratory workflows.
Pouch Prismatic Battery OCV DCIR Testing Machine with Barcode Scanning and Inkjet Coding
Automated pouch prismatic battery OCV and DCIR testing machine with barcode scanning, voltage resistance measurement, data traceability, and OK NG sorting for high throughput cell production across pouch cell manufacturing lines with reliable server integration
Manual OCV Multifunction Test Sorting Machine
Manual OCV multifunction test sorting machine for pouch lithium ion prismatic cells combines voltage and internal resistance grading data binding database storage and operator guided handling for controlled battery production inspection with computer display and configurable audible grade notification.
Prismatic Battery Automatic Testing and Sorting Equipment
Prismatic battery automatic testing and sorting equipment measures open circuit voltage and AC internal resistance, automatically pairs up to eight grades, supports traceable database management, and processes approximately 600 cells per hour for consistent pack quality in lithium battery production.
Double Sided Automatic Spot Welder for Lithium Ion Battery Pack Production
Double sided automatic spot welder for lithium-ion battery pack production, delivering synchronized resistance welding, 0.02mm positioning accuracy, AI inspection, traceable process data, and configurable high-throughput automation for EV, energy storage, power tool, and consumer battery manufacturing lines worldwide.
Fully Automatic Lithium Ion Battery Electrode Sheet Die Cutting Machine
Fully automatic lithium ion battery electrode sheet die cutting machine integrates unwinding, alignment, tab forming, CCD inspection, dust removal and rewinding for accurate high speed continuous coated electrode production.
Fully Automatic Lithium Battery Positive and Negative Electrode Sheet Making Machine with Tab Welding and Automatic Rewinding
Fully automatic lithium battery electrode sheet making machine integrates ultrasonic tab welding protective tape application inspection dust collection and precision rewinding for positive and negative electrode production with reliable alignment high yield and consistent cell manufacturing performance.
Single Sided Battery Electrode Extrusion Coating Machine
Single-sided battery electrode coating machine delivers precise intermittent and continuous slurry application, stable web tension, controlled electric drying, and consistent coatings for lithium-ion battery research, pilot production, and advanced materials development across demanding laboratory and development workflows every day.
High Precision Lithium Battery Electrode Sheet Calendering Machine
High precision lithium battery electrode sheet calendering machine delivers controlled compaction, adjustable roll gaps, 4000 kN line pressure, accurate tension handling, and consistent electrode density for demanding cell manufacturing lines.
Lithium Battery Electrode Sheet Continuous Slitting Machine 200 to 560 mm Slitting Width
Continuous lithium battery electrode sheet slitting machine processes rolled coated electrodes across 200 to 560 mm widths with closed loop tension control precision web guiding dust removal and dual differential shaft rewinding.
Semi Automatic Electrode Laser Cutting Machine
Semi automatic electrode laser cutting machine for lithium ion battery pilot lines delivers fast precision cutting clean dust control reliable handling and consistent production performance with simple software rapid changeover stable fiber laser and high yield results for advanced research
Automatic Coating Film Drying Machine Lithium Battery Laboratory Coating Machine
Automatic coating film drying machine and lithium battery laboratory coating machine with 130°C heating, adjustable coating speed, vacuum plate, precision scraper, programmable drying timer for 18650 electrode research smooth reproducible coatings across varied substrates compact bench scale development applications
4680 Cylindrical Battery Detachable Split Test Kit
Detachable split test kit for 4680 cylindrical battery research with corrosion resistant sealing, stainless steel end caps, PTFE insulation, and secure spring loaded cell fastening for repeatable laboratory testing and flexible advanced materials workflows
Aqueous Battery Testing Fixture for Laboratory Cell Evaluation
Aqueous battery testing fixture for cells up to 20 mm internal diameter and 4 mm thickness, featuring a 50 mm diameter clamp, PI film window, PEEK insulation, and high-purity titanium metal components for adaptable laboratory evaluation of aqueous battery performance.
Automatic Lithium Battery Electrode Sheet Cross Cutting Slitting Machine
Automatic lithium battery electrode sheet cross cutting slitting machine provides programmable fixed length or optical tracking cuts, constant tension unwinding, adjustable speed, and low burr processing for positive and negative electrode production.
Dual Station Vacuum Automatic Electrolyte Filling Machine
Dual-station vacuum automatic electrolyte filling equipment for lithium battery production integrates two 16 dual-head pumps, automated positioning, vacuum processing, PLC control, safety protection, and fault alarms for controlled repeatable cell filling in demanding manufacturing workflows every day.
Prismatic Aluminum Case Battery Laser Welding System
Integrated laser welding system for prismatic aluminum case batteries combines top cover full seam and sealing pin welding with precise fixturing vision inspection protective gas and dust extraction for consistent high quality production in advanced battery manufacturing lines worldwide.
CT Testing Solid State Battery Device
CT testing solid state battery device for compact cell fixture evaluation with 2 mm inner diameter, optional display, external fixture, and 2 ton sensor integration for laboratory research workflows.